Heat Detector Alarm wholesale China

Navigation: Home> Health & Beauty Department > Safety > Heat Detector Alarm

Heat Detector

Item No:Sa9010760

-Ceiling or wall mounting-Easy installation-12VDC, 24VDC, 9V battery operated (included)-Detection of intense fires with fast response and the temperature.-Flash alarm indicator (red)-Safety-clip feature, not allow mounting of the heat alarm without battery installed-High stability and reliability-Relative Humidity: 10% ~ 95%-Operating Current: <30uA (standby) and 30mA (alarm working)-Horn level: 85dB within 1 meter-Operation: When the ambient temperature rise 70centigrade(or 60centigrade or 80centigrade)within 5 seconds, the alarm will sound.-Temperature Standard 70centigrade. (Can be adjusted for special location and customer request. )-Battery life: 1 year min- Interconnecting heat detector(1)Circuit for normally closed relay contacts(2)Circuit for normally opened relay contacts(3)Operating Frequency: 433 MHz/315MHz (optional)

Heat Detector

 

Heat Detector Alarm

Item No:Sa9010701

Heat Alarm Model No.:AS-010H -Ceiling or wall mounting -Easy installation -12VDC, 24VDC, 9V battery operated (included) -Detection of intense fires with fast response and the temperature. -Flash alarm indicator (red) -Safety-clip feature, not allow mounting of the heat alarm without battery installed -High stability and reliability -Relative Humidity: 10% ~ 95% -Operating Current: <30uA (standby) and 30mA (alarm working) -Horn level: 85dB within 1 meter -Operation: When the ambient temperature rise 70centigrade(or 60centigrade or 80centigrade)within 5 seconds, the alarm will sound. -Temperature Standard 70centigrade. (Can be adjusted for special location and customer request. ) -Battery life: 1 year min - Interconnecting heat detector (1)Circuit for normally closed relay contacts (2)Circuit for normally opened relay contacts (3)Operating Frequency: 433 MHZ/315MHZ (optional

Heat Detector Alarm

 

Heat Alarm

Item No:Sa9010688

The heat detector is designed to detect ambient temperature, generally it connect with main controller. The main controller checks the current. When ambient temperature reaches preset value or the temperature flare up to rise, the LED indicates alarm, and the current increase. Be suitable for the industrial and civil building where there is explosive and combustible gas.Specification:1)detecting temperature method: Rate of rise and fixed temperature2)voltage: 12VDC~30VDC3)alarm temperature: 65. o C4)static current: 4052924A~8052924A5)working humidity: 10~90%6)installing method: Ceiling installation7)The power current should not exceed 30mA8)After installing and switching on power, the detector is in operation state. When it detects that the ambient temperature is higher than preset alarm value or the temperature flare up to rise, the LED always light

Heat Alarm

 

<< 1  >>