Item No:Sa9010755
Technical parameters: Working voltage: AC230V50~60HZ Power dissipation: Less than 3W Use environment: Temperature: -10o C~50o C. Humidity: Less than 95% Alarm consistency: Gas 57993420345%LEL Alarm voice: More than 85dBProduct performance feature: This alarm is suitable for inspecting leakage of household gas. It is sensitive to liquefied gas, natural gas and coal gas used in cities, is convenient to install, simple operation, safe and reliable, economic and applied. When the gas consistency reaches alarm value, the alarm will send out alarm signal of sound and light, to remind you taking proper measures in time to avoid blast and poisoning.Operation: Put through electricity to preheat, yellow and green lights are bright, and the preheating time is less than 2 minutes, the alarm will not check gas when warming up, after preheating, yellow light is extinct, and the green is still bright, then enter inspection state, and when alarming, the green light will die, red light will shine. (note: Red light and green light are double-colour tube) button is for testing, alarm when pressing the button, and stop alarming when loosening it.Packing: Blister, 38x29x23CM/CTN, 12pieces/CTN, 3.5/3.0KGS/CTN.
Item No:Sa9010764
Technical parameters: 1. Power Source: 12VDC 2. Sensitivity: 10%LEL 3. Power Consumption: 1.7W 4. Operating Temperature: -10o C ~ 50o C 5. Ambient Humidity: 579934201695% RH 6. Alarm sonority: 57993422965 db 7. Product size: 10.7*10.7*3.7cm
Gas Detector with Shut Off Valve
Item No:Sa9010748
1. Operating Voltage: +12v DC or 230v 50Hz AC2.12v DC Standby Current: 50mA Approx3.230VAC Standby Wattage: 3.45W Approx4. Sounding Current: 150mA Approx5.12v DC Input Fuse Rating: 1 Amp (External)6.230v AC Input Fuse Rating: 3 Amp (In Plug)Shut off valve description:Valve description: Shut-off Automatically When it Alarm1. Valve body materials: Brass alloy2. Material for sealing: NBR rubber3. Operating temperature: -100C to +500C4. Test operating pressure: 10 KPa5. Connection style: G1/2"(DN15A) / G3/4"(DN20A)/G12"6. Valve opening: Reset manually
Item No:Sa9010747
1, Catalytical type sensor2, Power: 110VAC/220VAC/230VAC ( backup batteries), 12VDC/24VDC3, Working temperature: -10degree~60 degree4, Alarm density: Coal gas: 1000~5000ppm, Liquid petroleum gas: 1000~10000ppm,Natural gas: 1000ppm~5000ppm5, Interconnecting Gas detector(1)Circuit for normally closed rely contacts(2) Circuit for normally opened rely contacts(3)Operating Frequency: 433 MHZ/315MHZ (optional)6, Size: 166.26mm*90.26mm*36.50mm7, Weight: 430g/pc8, Package size: 60.0cm*41.6cm*28.5cm9, Quantity/Box: 50pcs10, CtnWei(kg): 19.1kg11, Q`CTY/20`FT: 21086pcs
Gas Detector with Shut Off Vlave
Item No:Sa9010745
Gas detector discription1, Semicondutor sensor2, Power: 110VAC/220VAC/230VAC, 12V-25VDC3, Alarm density: Coal gas: 1000~5000ppm, Liquid petroleum gas: 1000~10000ppm,Natural gas: 1000ppm~5000ppm5, Network function(1)Circuit for normally closed relay contacts(2) Circuit for normally opened relay contacts(3)Operating Frequency: 433 MHz/315MHz (optional)6, Size: 115mm*71mm*43mm7, Weight: 228g/PC8, Package size: 58.5cm*28.5cm*53.3cm9, Quantity/Box: 100PCS10, CtnWei(kg): 24.68kg11, Q`CTY/20`FT: 35200PCSShut off Valve description: Cut off the gas Automatically When it detect the gas leakageActuation voltage: DC 9VTemperature: -10centigrade~60 centigradeReset style: Manual resetBody material: BrassMaximum pressure: 25KpaResponse time: <0.3SConnection style: Screw thread
Item No:Sa9010739
gas alarm, is designed to detect the concentration of combustible, explosive and toxic gases, adopts high-quality gas sensor with advanced technology and superior craft. It provides visual and audible signals when the gas concentration reaches the presetting level. It reminds you to take prompt action. You may start up other link equipment, open windows or shut off gas supply to avoid fire, explosion, suffocation, and other malignant accidentsSpecifications:Working voltage: 220V AC 4984115%/110V AC 4984115% 50Hz or 12/24V DCConsumption: 5799342035WWorking condition:Temperature: 0 to 55 degreesHumidity: <95% RHResponse time: 57993420350s automatic resumeSampling method: natural diffusionAlarming method: visual and audibleAlarm sound: 57993422950dBWeight: 300gDimensions (L x W x H): 135 x 82 x 41mmOptional function: relay output and gas shut off valve output
Item No:Sa9010735
Main features:Automatic reset after alarmMCU processSensor with high stability and low power consumptionAutomatic check and indication for malfunctionDetecting natural gas and LPGSMT adoptedTechnology parameter:Operating voltage: 12 - 24V DCStandby current: less than 90mA or less than 30mA (low power consumption)Alarm current: less than 100mA or less than 40mA (low power consumption)Operating temp.: -10 to +5049840CWorking humidity: less than 95%RHAlarm mode: network output/sound and flash alarm/RFAlarm volume: more than 85dB/mAlarm density: 10% LELAlarm output: relay output (N.C.and N.O. optional)/RF signalDimension: 103 x 53mm deep
Item No:Sa9010725
Specification: *Detect item: All type of halogenated gas *Intensity of the leakage level *Rapid warm up time: Within 90s *The flexible probe can easily access any areas *Use the high effective mechanical pump to decrease the reactive time. *Ultimate sensitivity: 5AEJ1607 level standard, 0.5oz per year *Continuous operation time: 4hoursPacking information: *Power: 6V Ni-MH rechargeable battery *Net weight: 622g *Size: 234x86x46mm *Packing style: Gift box *Q'ty per carton: 12PCS *Standard carton size: 52.5x45.5x34.0cm *G. W of the carton: 17.5kg
Item No:Sa9010721
121by81by35mm Working voltage: AC/DC13.5 V(operating alone) DC24V(operating with fire alarm controller) Static power dissipation: 85db Sensitivity alarm: 1500ppm~3500ppm
Item No:Sa9010744
Main features:High reliability sensorAutomatic reset after alarmMCU processing adoptedAutomatic detect sensor failureInduced gas-CO/natural gas/LPG/LNG and moreSMT design, high stabilityWide work voltageWork with electrovalve and exhaust fanTechnology parameter:Operating voltage: 85 to 265V ACStatic current: 90 or 30mA (low power consumption type)Alarm current: 100 or 40mA (low power consumption type)Rating power: 3W (220V AC supply)Warm-up time: about 180 secondsAlarm level: 10% LEL gas and 100PPM carbon monoxideSound level: 70dB/mOperating temperature: -10 to +505798833549Environment humidity: 95% RHInstallation mode: wall mountedAlarm output: relay output/sound and flash alarmRF: 315MHz or 433MHz (wireless type)Radio distance: 100m in open area (wireless type)Outline size: 115 x 72 x 41mmExecute criterion: EN50291/GB15322.2-2003